Class A storage areas
The largest Logistics Center of class " A " is located in the Chekhov district of the Moscow region, 50 kilometers from the Moscow Ring Road along Simferopol Highway (M2) in the South direction, between two ring roads A-107 and A-108, with transport accessibility of no more than 20 kilometers.
On the territory of the logistics complex there are four class A warehouses with a useful storage area of 28000m2, 22500 m2, 5000 m2, 5850 m2.
Convenient transport interchange for all directions
Any questions? Ask them now!
Warehouse characteristics
- Roof: flat, insulated with an organized drainage system
- Walls: sandwich panels, mineral wool 150 mm is used as insulation.
- Warehouse lighting: natural and artificial
- Ceiling height: 12 m.
- Built-in administrative and office premises with a total area of 3400 m2.
- The warehouses are equipped with docks with docklovers and dockshelters made by HORMANN.
- Fire protection system: splinker system, fire cranes, APS, SSE. The warehouses are equipped with ventilation, heating, and power supply systems.
- Own railway line with the possibility of loading/unloading cargo
- Video surveillance with archive depth of 60 days
- Access control and management system
|
FACILITIES AND COMMUNICATIONS |
specifications |
|
1. Energy supply |
|
|
Energy supply category |
The second |
|
Permitted power |
5.1 MW |
|
External power supply |
10 kV |
|
Internal power supply |
0.4kV |
|
Number of substations |
4 |
|
Substation characteristics |
2x1000kVA, 5x630kVA |
|
Availability of energy supply |
at all facilities |
|
Backup power supply |
400kW Diesel Generator 160kW diesel Generator |
|
2. Heat supply |
|
|
Automated boiler rooms |
7.1 MW |
|
The main type of fuel |
Gas |
|
Reserve type of fuel |
Diesel, 50 m3 |
|
Availability of heat supply |
at all facilities |
|
3.Water supply |
|
|
Water intake unit |
There are |
|
Number of wells drilled |
4 x 67 meters |
|
Availability of water supply |
at all facilities |
|
4.Sewage system |
|
|
Sewage treatment plants |
Storm drains |
|
Sewage system |
Storage and treatment facilities |
|
Availability of household sewerage |
at all facilities |
|
5.Fire extinguishing system |
|
|
Fire extinguishing pumping station |
there is |
|
Fire tank |
4x750 cubic meters |
|
Availability of a fire extinguishing system |
at all facilities |